Description
-
This is a combination gas + particle (aerosol) filter (i.e. it protects against both gases/vapors and particulates).
-
It uses a bayonet connection (side-mount) compatible with Dräger masks with bayonet fittings (for example, X‑plore 3300, 3500 half‑masks, X‑plore 5500 full‑face masks)
-
The “R” marking indicates it is reusable across multiple work shifts (i.e. not strictly single use) under appropriate conditions.
-
It is sold in packs (pairs or multiples) and individually vacuum sealed for shelf life preservation.
Markings & What They Mean (A1B1E1K1HgP3 R D)
Here’s a breakdown of each component:
| Marking | What It Protects Against |
|---|---|
| A1 | Organic gases and vapours (with boiling point > 65 °C) |
| B1 | Inorganic gases and vapours (except CO) |
| E1 | Acid gases (e.g. sulfur dioxide, hydrogen chloride) |
| K1 | Ammonia and organic ammonia derivatives |
| Hg | Mercury vapour protection |
| P3 | High level particulate filtration (solid and liquid aerosols) |
| R | Reusable (i.e. can be used over multiple shifts) |
| D | Indicates it has passed the dolomite clogging test (i.e. it meets an extra standard of performance under dusty / clogging conditions) |
The “D” (dolomite test) is significant: it means it remains usable / breathable even when exposed to fine dust load (i.e. it resists clogging more so than filters without that mark).
Technical Specifications / Performance Data
Here are more specific technical details:
-
Standards / Certification: EN 14387 (for gas/combo filters) and EN 143 (for particle filters)
-
Weight: approx. 140 g per piece (as stated in one datasheet)
-
Filter Housing & Design:
-
Robust plastic housing with splash protection and hydrophobic paper to prevent moisture ingress
-
Low airflow resistance due to pleated filter media and wide internal cavity design
-
Filters are vacuum sealed to maintain shelf life; shelf life for gas/combo filters is generally 6 years (if stored unopened, under correct conditions)
-
-
Usage / Replacement Guidance:
-
The filter must be replaced when you detect breakthrough (i.e. smell, taste) of gases, or if breathing resistance becomes too high due to particulate loading
-
The filter cannot be disassembled: the gas & particle portions are integrated and cannot be replaced separately. If one part is used up (e.g. particle filter clogged), the entire unit must be replaced.
-
Storage after use: must be placed back in airtight, dry, cool conditions if reusing for another shift (if allowed by the “R” rating)
-
-
Compatibility: Meant for Dräger masks with bayonet connection: X‑plore 3300, 3500, 5500, etc.
-
Part / Catalog Number: 6738817 is a commonly referenced catalog / part number for this filter.