- 5SR (5 lb. Semi-Recessed): Elite Series 8 x 17 x 5 Semi-Recessed Cabinet accommodates 5 lb extinguishers. Tub 22 ga. (0.75 mm); Flush SS Paddle Latch; 16 ga. Door & Trim (1.5 mm) & 22 ga. Tub (.75 mm); 1" turnback (return frame) allows for installation in a 4wall; Welded tub and front trim ; Full viewing panel (4x 13acrylic panel, #A413 sold separately); Grey baked enamel finish; Glass clips included; Full-length semi-concealed piano hinges; Flush stainless steel door paddle latches; SKU: 5SR; Applications: 5 lb. Dry Chem Extgrs; Style: Semi-Recessed; Material: Steel; Colour: Grey; Ship Weight (lbs): 9.1; Turnback (In.): 1; Min Wall Depth (In.): 4; Front Type: Full Glass; Glass Size (In.): 4 x 13; Door & Trim: 16 ga. (1.5 mm); Constuction: Welded tub and front
- 5FR (5 lb. Fully Recessed): Elite Series 8 x 17 x 5 Fully Recessed Cabinet accommodates 5 lb extinguishers.; Tub 22 ga. (0.75 mm); Flush SS Paddle Latch; 16 ga. Door & Trim (1.5 mm) & 22 ga. Tub (.75 mm); Full viewing panel (4x 13acrylic panel, #A413 sold separately); Grey baked enamel finish; Accommodates a 5 lb. dry chemical extinguisher; Glass clips included; Full-length semi-concealed piano hinges; Flush stainless steel door paddle latches; SKU: 5FR; Applications: 5 lb. Dry Chem Extgrs; Style: Fully-Recessed; Material: Steel; Colour: Grey; Ship Weight (lbs): 9.1; Turnback (In.): 0.25; Min Wall Depth (In.): 5; Front Type: Full Glass; Glass Size (In.): 4 x 13; Door & Trim: 16 ga. (1.5 mm); Constuction: Welded tub and front
- 10SR (10 lb. Semi-Recessed): Elite Series 9 x 24 x 6 Semi Recessed Cabinet accommodates 10 lb extinguishers.; Tub 22 ga. (0.75 mm); Flush SS Paddle Latch; 16 ga. Door & Trim (1.5 mm) & 22 ga. Tub (.75 mm); 2turnback (return frame) allows for installation in a 4wall; Welded tub and front ; Full viewing panel (5x 20acrylic panel, #A520 sold separately); Grey baked enamel finish; Glass clips included; Full-length semi-concealed piano hinges; Flush stainless steel door paddle latches; SKU: 10SR; Applications: 10 lb. Dry Chem Extgrs; Style: Semi-Recessed; Material: Steel; Colour: Grey; Ship Weight (lbs): 15.5; Turnback (In.): 2; Min Wall Depth (In.): 4; Front Type: Full Glass; Glass Size (In.): 5 X 20; Door & Trim: 16 ga. (1.5 mm); Constuction: Welded tub and front
- 10FR (10 lb. Fully Recessed): Elite Series 9 x 24 x 6 Fully Recessed Cabinet accommodates 10 lb extinguishers.; Tub 22 ga. (0.75 mm); Flush SS Paddle Latch; 16 ga. Door & Trim (1.5 mm) & 22 ga. Tub (.75 mm); Welded tub and front; Full viewing panel (5x 20acrylic panel, #A520 sold separately); Grey baked enamel finish; Glass clips included; Full-length semi-concealed piano hinges; Flush stainless steel door paddle latches; SKU: 10FR; Applications: 10 lb. Dry Chem Extgrs; Style: Fully-Recessed; Material: Steel; Colour: Grey; Ship Weight (lbs): 15; Turnback (In.): 0.25; Min Wall Depth (In.): 6; Front Type: Full Glass; Glass Size (In.): 5 X 20; Door & Trim: 16 ga. (1.5 mm); Constuction: Welded tub and front
More Info
Extinguisher Cabinet for Recessed Storage
The Fully/Semi-Recessed Extinguisher Cabinet is a recessed cabinet designed for discreet, wall-integrated storage and display of fire extinguishers. Facility managers, maintenance technicians, and fire safety officers typically use this cabinet to keep a fire extinguisher accessible while preserving corridor aesthetics. The steel construction, welded tub, and stainless steel paddle latch provide a durable housing for 5 lb or 10 lb dry chemical extinguishers.
Industry Applications and Professional Use
Emergency Services
Fire safety officers and first responders often specify recessed fire cabinet locations in stations and public facilities to ensure quick visual access to a fire extinguisher. These cabinets allow crews to check extinguishers during routine rounds while maintaining a neat wall profile. The full glass viewing option helps teams monitor extinguisher presence without opening the door.
Building Maintenance and Property Management
Facility managers and building inspectors commonly install semi-recessed or fully-recessed cabinets in corridors and lobbies to reduce obstruction and preserve interior design. Maintenance crews perform periodic visual checks through the acrylic viewing panel and replace parts per manufacturer instructions when needed. The grey baked enamel finish fits many commercial interiors.
Manufacturing and Warehousing
Safety coordinators and maintenance technicians typically choose 10 lb capacity cabinets for warehouse floor coverage and industrial workspaces. The welded steel tub and full-length piano hinge support occasional-use conditions and withstand routine handling. Workers appreciate the clear front for quick verification of extinguisher readiness.
Construction and Municipal Facilities
Contractors and municipal services often use recessed cabinet SKUs during new builds or renovations to save corridor space and meet building code visibility needs. Installers select the appropriate turnback and minimum wall depth for semi-recessed or fully-recessed installation. The cabinet suits both functional and aesthetic project goals.
Technical Specifications and Product Features
Understanding Product Standards
Technical specs matter because installation depth, material gauge, and latch type affect fit and long-term performance. Designers and installers evaluate door trim gauge, tub gauge, and viewing panel size to match extinguisher type and wall construction. The cabinets balance recessed design with welded steel construction for durable indoor storage.
| Specification | What It Means | Practical Benefit |
|---|---|---|
| Material: Steel; Door & Trim: 16 ga.; Tub: 22 ga. | Steel gauges indicate door and tub thickness for structural strength. | Provides a sturdy housing for 5 lb and 10 lb dry chemical fire extinguishers. |
| Latch: Flush stainless steel paddle latch; Hinges: Piano hinge | Flush latch and semi-concealed full-length hinge give a low-profile door. | Maintains corridor aesthetics and offers reliable access when needed. |
| Viewing Panel: Full Glass (acrylic panels sold separately) | Acrylic panels allow visual checks without opening the door; sizes: 4 x 13 in (5 lb), 5 x 20 in (10 lb). | Enables quick verification of extinguisher presence and type during inspections. |
| Dimensions & Installation Depth (SKUs) | 5SR/5FR: 8 x 17 x 5 in; 10SR/10FR: 9 x 24 x 6 in; Turnback and min wall depth vary by SKU. | Helps installers choose semi-recessed or fully-recessed cabinet to match wall depth and return frame needs. |
Use Case Scenarios and Applications
Indoor Recessed Installation
This recessed cabinet category typically installs in interior walls, corridors, and lobbies where saving floor space matters. Installers select semi- or fully-recessed SKUs based on wall depth and desired return frame (turnback). The welded tub and steel door trim help the cabinet withstand routine building traffic.
Occasional-Use Fire Response
Sites that rely on occasional emergency access commonly pair these cabinets with 5 lb or 10 lb dry chemical extinguishers. The full-view option supports quick visual checks without opening the door. Workers performing visual inspections can verify extinguisher presence rapidly.
Building-Integrated Aesthetics
Architects and contractors usually specify the grey baked enamel finish and flush paddle latch where aesthetics matter. The cabinet integrates with wall finishes while providing a clear viewing panel option for safety personnel. This approach keeps extinguisher storage discreet yet visible.
Ideal Applications and Work Environments
Where This Extinguisher Cabinet Excels
- Commercial office buildings : Semi- or fully-recessed units provide discreet storage and allow visual checks via acrylic panel.
- Retail centres and malls : Flush-mounted grey cabinets match interior design while keeping fire extinguisher access clear.
- Industrial warehouses : 10 lb capacity SKUs with welded steel tub suit heavy-duty storage and occasional handling.
- Multi-unit residential & municipal buildings : Semi-recessed cabinets save corridor space and meet visibility expectations for inspections.
Not Recommended For
- Outdoor or unheated locations : Cabinets may not suit exterior exposure; consider outdoor-rated enclosures designed for weather resistance.
- Specialized hazardous locations : Cabinets without specific environmental ratings may not meet needs for corrosive or extreme-temperature settings; evaluate specialty enclosures.
Professional Applications
Workers Who Rely on This Equipment
- Facility Managers : Specify cabinet SKUs and oversee placement to meet corridor layout and inspection routines.
- Maintenance Technicians : Install and perform routine checks and replace acrylic viewing panels per manufacturer instructions.
- Fire Safety Officers : Use viewing panels to confirm presence of a fire extinguisher during safety audits.
- Building Inspectors : Verify correct cabinet type and installation depth for compliance with local codes.
- Contractors : Coordinate return frame (turnback) and wall depth during construction or renovation projects.
Complete Safety Equipment Solutions
Complementary Safety Gear
The recessed cabinet works alongside fire extinguishers, fire alarm systems, emergency lighting, and safety signage to form a comprehensive response strategy. Sites typically layer equipment to address visibility, access, and notification needs. This multi-component approach supports routine checks and emergency readiness.
Recommended Equipment Combinations
- Office corridor : Fully/Semi-Recessed Extinguisher Cabinet + 5 lb fire extinguisher + emergency lighting + safety signage
- Warehouse floor : 10 lb recessed cabinet + dry chemical extinguisher + fire alarm system
- Lobby or retail : Semi-recessed cabinet + acrylic viewing panel + visible safety signage
Selection Guide and Product Suitability
When to Choose This Product
Choose semi-recessed models when you need a return frame (turnback) to fit thinner walls. Choose fully-recessed models when you have adequate wall depth and want the door nearly flush with the wall. Select 5 lb or 10 lb SKUs based on expected coverage area and extinguisher type.
Key Evaluation Factors
- Minimum wall depth and installation depth for the chosen SKU
- Turnback (return frame) size required for semi-recessed installation
- Viewing panel size and whether acrylic panels will be purchased separately
- Material gauge, welded steel construction, and latch style for durability
Limitations and Alternative Considerations
This recessed cabinet generally suits interior, climate-controlled locations and may not be appropriate for outdoor or corrosive environments; consider outdoor-rated enclosures as an alternative. All Safety offers flexible ordering with standard, expedited, or overnight shipping to suit project timelines.
Daily Use and Maintenance
Workplace Integration
Install cabinets in corridors, lobbies, and service areas where staff perform routine visual checks per manufacturer instructions. Use the acrylic viewing panel option for quick verification of extinguisher presence without opening the door. Communicate cabinet locations to staff during safety briefings.
Care and Replacement Guidelines
Inspect cabinets and viewing panels periodically per manufacturer instructions and replace damaged doors, latches, or panels immediately if compromised. Clean painted steel and acrylic panels with mild detergent and a non-abrasive cloth as recommended by the manufacturer. Store spare acrylic panels and hardware in dry, temperature-controlled conditions per manufacturer guidance.
Ordering and Delivery
How to Order and Shipping Options
Order cabinets by SKU (5SR, 5FR, 10SR, 10FR) to match extinguisher size and installation depth. All Safety ships products with common options and can advise on selecting the correct recessed cabinet based on wall depth and turnback requirements. Shipping options typically include standard, expedited, or overnight shipping to accommodate project schedules.