BUY IN BULK & SAVE | $250+ = FREE SHIPPING | $500+ = 5% OFF + FREE SHIPPING | $1000+ = 7% OFF + FREE SHIPPING | $2000+ = 10% OFF + FREE SHIPPING | DISCOUNT APPLIED TO CART

Battery Unit

(No reviews yet) Write a Review
SKU:
EB
  • Battery Unit EB
  • Battery Unit EB
  • Battery Unit EB
  • Battery Unit EB
  • Battery Unit EB
  • Battery Unit EB
  • Battery Unit EB
$208.03 - $1,779.39

Description

Battery Unit | Steel Fire

EBST series of commercial steel battery units are designed to provide efficient and reliable emergency lighting. Utilizing a sturdy, all steel housing, the EBST presents a modern and unobtrusive design.

 

Available Options

  • EB1236-2SM-3LJ (12V 36W 3W LED Heads): 3-1/2 ft line cord included; 12VDC 36W Battery Capacity (30 minute duration); Standard with 3W LED PAR18 heads; 120/347 VAC input; Steel Construction; CSA Certified to C22.2 #141.15; SKU: EB1236-2SM-3LJ; Listing: CSA; Width (In.): 12.25; Height (In.): 10.375; Depth (In.): 2.975; Voltage: 12; Max Watt : 36; 30 Mins: 120/347; Input VAC: 2 x Par 18; Heads Style: 3W LED; Lamp: 2 x 6V5Ah; Battery:
  • EB6362 (6V 36W): 3-1/2 ft line cord included; 6VDC; 36 Watt Capacity @ 30 minute duration; Comes with 6V 5.0Ah battery; Standard with PAR18 heads; 120/347 VAC input; Steel Construction; CSA Certified to C22.2 #141.15; SKU: EB6362; Listing: CSA; Width (In.): 12.25; Height (In.): 10.375; Depth (In.): 2.975; Voltage: 6; Max Watt : 36; 30 Mins: 120/347; Input VAC: 2 x Par 18; Heads Style: 9W T; Lamp: 1 x 6V5Ah; Battery:
  • EB12722 (12V 72W): 3-1/2 ft line cord included; 12VDC; 72 Watt Capacity @ 30 minute duration; Comes with two (2) 6V 5Ah batteries; Standard with PAR18 heads; 120/347 VAC input; Steel Construction; CSA Certified to C22.2 #141.15; SKU: EB12722; Listing: CSA; Width (In.): 12.25; Height (In.): 10.375; Depth (In.): 2.975; Voltage: 12; Max Watt : 72; 30 Mins: 120/347; Input VAC: 2 x Par 18; Heads Style: 9W T; Lamp: 2 x 6V5Ah; Battery:
  • EB121002 (12V 100W): 3-1/2 ft line cord included; 12VDC; 100 Watt Capacity @ 30 minute duration; Comes with one 12V 7.2Ah batteries; Standard with PAR18 heads; 120/347 VAC input; Steel Construction; CSA Certified to C22.2 #141.15; SKU: EB121002; Listing: CSA; Width (In.): 10; Height (In.): 13.5; Depth (In.): 3.287; Voltage: 12; Max Watt : 100; 30 Mins: 120/347; Input VAC: 2 x Par 18; Heads Style: 9W T; Lamp: 1 x 12V7.2Ah; Battery:
  • EB12100-2SM-3LJ (12V 100W 3W LED Heads): 3-1/2 ft line cord included; 12VDC 100W Battery Capacity (30 minute duration); Standard with 3W LED PAR18 heads; 120/347 VAC input; Steel Construction; CSA Certified to C22.2 #141.15; SKU: EB12100-2SM-3LJ; Listing: CSA; Width (In.): 10; Height (In.): 13.5; Depth (In.): 3.287; Voltage: 12; Max Watt : 100; 30 Mins: 120/347; Input VAC: 2 x Par 18; Heads Style: 3W LED; Lamp: 1 x 12V7.2Ah; Battery:
  • EB61002 (6V 100W): 3-1/2 ft line cord included; 6VDC; 100 Watt Capacity @ 30 minute duration; Comes with two (2) 6V 7.2Ah battery; Standard with PAR18 heads; 120/347 VAC input; Steel Construction; CSA Certified to C22.2 #141.15; SKU: EB61002; Listing: CSA; Width (In.): 10; Height (In.): 13.5; Depth (In.): 3.287; Voltage: 6; Max Watt : 100; 30 Mins: 120/347; Input VAC: 2 x Par 18; Heads Style: 9W T; Lamp: 2 x 6V7.2Ah; Battery:
  • EB241442 (24V 144W): 3-1/2 ft line cord included; 24VDC; 144 Watt Capacity @ 30 minute duration; Comes with four (4) 6V 5Ah battery; Standard with PAR18 heads; 120/347 VAC input; Steel Construction; CSA Certified to C22.2 #141.15; SKU: EB241442; Listing: CSA; Width (In.): 14.25; Height (In.): 14.625; Depth (In.): 4.262; Voltage: 24; Max Watt : 144; 30 Mins: 120/347; Input VAC: 2 x Par 18; Heads Style: 9W T; Lamp: 4 x 6V5Ah; Battery:
  • EB121602 (12V 160W): 3-1/2 ft line cord included; 12VDC; 160 Watt Capacity @ 30 minute duration; Comes with two (2) 6V 12Ah batteries; Standard with PAR18 heads; 120/347 VAC input; Steel Construction; CSA Certified to C22.2 #141.15; SKU: EB121602; Listing: CSA; Width (In.): 14.25; Height (In.): 14.625; Depth (In.): 4.262; Voltage: 12; Max Watt : 160; 30 Mins: 120/347; Input VAC: 2 x Par 18; Heads Style: 9W T; Lamp: 2 x 6V12Ah; Battery:
  • EB61602 (6V 160W): 3-1/2 ft line cord included; 6VDC; 160 Watt Capacity @ 30 minute duration; Comes with two (2) 6V 12Ah battery; Standard with PAR18 heads; 120/347 VAC input; Steel Construction; CSA Certified to C22.2 #141.15; SKU: EB61602; Listing: CSA; Width (In.): 14.25; Height (In.): 14.625; Depth (In.): 4.262; Voltage: 6; Max Watt : 160; 30 Mins: 120/347; Input VAC: 2 x Par 18; Heads Style: 9W T; Lamp: 2 x 6V12Ah; Battery:
  • EB122002 (12V 200W): 3-1/2 ft line cord included; 12VDC; 200 Watt Capacity @ 30 minute duration; Comes with two (2) 12V 7.2Ah batteries; Standard with PAR18 heads; 120/347 VAC input; Steel Construction; CSA Certified to C22.2 #141.15; SKU: EB122002; Listing: CSA; Width (In.): 14.25; Height (In.): 14.625; Depth (In.): 4.262; Voltage: 12; Max Watt : 200; 30 Mins: 120/347; Input VAC: 2 x Par 18; Heads Style: 9W T; Lamp: 2 x 12V7.2Ah; Battery:
  • EB242002 (24V 200W): 3-1/2 ft line cord included; 24VDC; 200 Watt Capacity @ 30 minute duration; Comes with two (2) 12V 7.2Ah battery; Standard with PAR18 heads; 120/347 VAC input; Steel Construction; CSA Certified to C22.2 #141.15; SKU: EB242002; Listing: CSA; Width (In.): 14.25; Height (In.): 14.625; Depth (In.): 4.262; Voltage: 24; Max Watt : 200; 30 Mins: 120/347; Input VAC: 2 x Par 18; Heads Style: 9W T; Lamp: 2 x 12V7.2Ah; Battery:
  • EB122502 (12V 250W): 3-1/2 ft line cord included; 12VDC; 250 Watt Capacity @ 30 minute duration; Comes with one 12V 32Ah batteries; Standard with PAR18 heads; 120/347 VAC input; Steel Construction; CSA Certified to C22.2 #141.15; SKU: EB122502; Listing: CSA; Width (In.): 12.9; Height (In.): 14.625; Depth (In.): 8.524; Voltage: 12; Max Watt : 250; 30 Mins: 120/347; Input VAC: 2 x Par 18; Heads Style: 9W T; Lamp: 1 x 12V32Ah; Battery:
  • EB243202 (24V 320W): 3-1/2 ft line cord included; 24VDC; 320 Watt Capacity @ 30 minute duration; Comes with four (4) 6V 12Ah battery; Standard with PAR18 heads; 120/347 VAC input; Steel Construction; CSA Certified to C22.2 #141.15; SKU: EB243202; Listing: CSA; Width (In.): 12.9; Height (In.): 14.625; Depth (In.): 8.524; Voltage: 24; Max Watt : 320; 30 Mins: 120/347; Input VAC: 2 x Par 18; Heads Style: 9W T; Lamp: 4 x 6V12Ah; Battery:
  • EB243502 (24V 350W): 3-1/2 ft line cord included; 24VDC; 350 Watt Capacity @ 30 minute duration; Comes with two (2) 12V 7.2Ah battery; Standard with PAR18 heads; 120/347 VAC input; Steel Construction; CSA Certified to C22.2 #141.15; SKU: EB243502; Listing: CSA; Width (In.): 18.13; Height (In.): 14.625; Depth (In.): 8.524; Voltage: 24; Max Watt : 350; 30 Mins: 120/347; Input VAC: 2 x Par 18; Heads Style: 9W T; Lamp: 2 x 12V7.2Ah; Battery:
  • EB123602 (12V 360W): 3-1/2 ft line cord included; 12VDC; 360 Watt Capacity @ 30 minute duration; Comes with one 12V 35Ah battery; Standard with PAR18 heads; 120/347 VAC input; Steel Construction; CSA Certified to C22.2 #141.15; SKU: EB123602; Listing: CSA; Width (In.): 12.9; Height (In.): 14.625; Depth (In.): 8.524; Voltage: 12; Max Watt : 360; 30 Mins: 120/347; Input VAC: 2 x Par 18; Heads Style: 9W T; Lamp: 1 x 12V35Ah; Battery:
  • EB245502 (24V 550W): 3-1/2 ft line cord included; 24VDC; 550 Watt Capacity @ 30 minute duration; Comes with two (2) 12V 32Ah battery; Standard with PAR18 heads; 120/347 VAC input; Steel Construction; CSA Certified to C22.2 #141.15; SKU: EB245502; Listing: CSA; Width (In.): 18.13; Height (In.): 14.625; Depth (In.): 8.524; Voltage: 24; Max Watt : 550; 30 Mins: 120/347; Input VAC: 2 x Par 18; Heads Style: 9W T; Lamp: 2 x 12V32Ah; Battery:
  • EB247202 (24V 720W): 3-1/2 ft line cord included; 24VDC; 720 Watt Capacity @ 30 minute duration; Comes with two (2) 12V 35Ah battery; Standard with PAR18 heads; 120/347 VAC input; Steel Construction; CSA Certified to C22.2 #141.15; SKU: EB247202; Listing: CSA; Width (In.): 18.13; Height (In.): 14.625; Depth (In.): 8.524; Voltage: 24; Max Watt : 720; 30 Mins: 120/347; Input VAC: 2 x Par 18; Heads Style: 9W T; Lamp: 2 x 12V35Ah; Battery:
  • EB6362HP (6V 36W High Capacity): 3-1/2 ft line cord included; 6VDC; 36 Watt Capacity @ 30 minute duration; Comes with 6V 7.2Ah battery for longer performance (std units are 6V 5Ah battery); Standard with PAR18 heads; 120/347 VAC input; Steel Construction; CSA Certified to C22.2 #141.15; SKU: EB6362HP; Listing: CSA; Width (In.): 12.25; Height (In.): 10.375; Depth (In.): 2.975; Voltage: 6; Max Watt : 36; 30 Mins: 120/347; Input VAC: 2 x Par 18; Heads Style: 9W T; Lamp: 1 x 6V7.2Ah; Battery:
  • EB650-2SM-3LJ (6V 50W 3W LED Heads): 3-1/2 ft line cord included; 6VDC 50W Battery Capacity (30 minute duration); Standard with 3W LED PAR18 heads; 120/347 VAC input; Steel Construction; CSA Certified to C22.2 #141.15; SKU: EB650-2SM-3LJ; Listing: CSA; Width (In.): 12.25; Height (In.): 10.375; Depth (In.): 2.975; Voltage: 6; Max Watt : 50; 30 Mins: 120/347; Input VAC: 2 x Par 18; Heads Style: 3W LED; Lamp: 1 x 6V7.2Ah; Battery:
  • EB6722 (6V 72W): 3-1/2 ft line cord included; 6VDC; 72 Watt Capacity @ 30 minute duration; Comes with one 6V 12Ah battery; Standard with PAR18 heads; 120/347 VAC input; Steel Construction; CSA Certified to C22.2 #141.15; SKU: EB6722; Listing: CSA; Width (In.): 10; Height (In.): 13.5; Depth (In.): 3.287; Voltage: 6; Max Watt : 72; 30 Mins: 120/347; Input VAC: 2 x Par 18; Heads Style: 9W T; Lamp: 1 x 6V12Ah; Battery:
  • EB672-2SM-3LJ (6V 72W 3W LED Heads): 3-1/2 ft line cord included; 6VDC 72W Battery Capacity (30 minute duration); Standard with 3W LED PAR18 heads; 120/347 VAC input; Steel Construction; CSA Certified to C22.2 #141.15; SKU: EB672-2SM-3LJ; Listing: CSA; Width (In.): 10; Height (In.): 13.5; Depth (In.): 3.287; Voltage: 6; Max Watt : 72; 30 Mins: 120/347; Input VAC: 2 x Par 18; Heads Style: 3W LED; Lamp: 1 x 6V12Ah; Battery:

More Info

Emergency Battery Unit for Commercial Emergency Lighting

Electricians, facility managers, and maintenance technicians working in commercial and institutional buildings rely on the Battery Unit to provide backup emergency lighting and short-duration illumination during power outages. This emergency battery unit is designed for indoor, code-listed emergency lighting with a steel housing, PAR18 heads, and 120/347 VAC input and is CSA Certified to C22.2 #141.15.

Industry Applications and Professional Use

Emergency Services

First responders and building emergency teams typically deploy Battery Unit systems in command centers and staging areas to maintain emergency lighting and orientation during outages. Units with LED emergency head options and compact steel housings often support rapid installation and reliable short-term illumination.

Municipal Services

Municipal facilities commonly use these emergency battery units to keep corridors, lobbies, and public service desks lit during interruptions. Multiple voltage options and CSA listing help municipalities select units that integrate with existing fire and alarm systems.

Manufacturing

Manufacturing plants typically rely on higher wattage configurations to power task-area emergency lighting for safe shutdown and egress. The range of wattage capacity across SKUs supports large-scale deployments in production zones and maintenance areas.

Utilities and Transportation

Utilities, transit hubs, and transportation facilities often use robust steel housings and higher-capacity units to illuminate critical pathways and control rooms during outages. SKU configurations with multiple battery cells provide the wattage capacity many utility sites require.

Warehousing

Warehouse operators typically select higher-wattage Battery Unit models to keep aisles and loading areas visible long enough for orderly response and material handling. Units with PAR18 heads and 30 minute runtime ratings often fit code-driven emergency lighting strategies.

Technical Specifications and Product Features

Understanding Product Standards

Technical specifications influence installation wiring, runtime, and compatibility with emergency lighting fixtures; designers and electricians typically assess wattage capacity, voltage options, and listed certifications when specifying units. The EBST series offers multiple voltages (6V, 12V, 24V), wattage capacities from 36W to 720W, and PAR18 heads in LED and standard lamp variants.

Specification What It Means Practical Benefit
CSA Certified to C22.2 #141.15 Third-party listing for emergency lighting battery units in Canada Helps demonstrate code compliance for commercial emergency lighting projects
120/347 VAC input Dual-voltage AC input common in commercial electrical systems Allows straightforward integration with building wiring and panels
30 minute runtime / Wattage capacities (36W–720W) Rated emergency duration at specified wattage output Enables selection of unit capacity to match emergency lighting loads
PAR18 heads (3W LED or 9W T options) Standard head style for focused emergency illumination Offers selectable lamp performance and energy-efficient LED choices

What does 120/347 VAC input mean and how does it affect installation?

120/347 VAC denotes compatibility with common building supplies and allows installers to hardwire the unit to either standard 120V or 347V circuits typically found in commercial and institutional settings. Electricians generally follow manufacturer instructions and local code when connecting line power and verifying voltage selection.

Use Case Scenarios and Applications

Indoor Corridor and Exit Illumination

In office, retail, and healthcare corridors the Battery Unit typically powers PAR18 heads to keep exit routes visible during brief outages. Installers often choose compact dimensions for retrofit locations where fixture depth and width matter.

Large-Scale Facility Backup

Warehouses and manufacturing plants often deploy high-capacity models (200W–720W) to supply multiple emergency fixtures and task-area lighting during an outage. Design teams typically map wattage capacity against fixture load to select the correct SKU configuration.

Occasional or Standby Emergency Use

For spaces with intermittent emergency requirements, units with 3W LED heads and sealed lead-acid battery options provide energy-efficient standby illumination and simpler maintenance. Maintenance teams usually schedule monthly functional tests per manufacturer recommendations.

Ideal Applications and Work Environments

Where This Emergency Battery Unit Excels

  • Commercial building corridors: CSA-listed units with PAR18 heads and 30 minute runtime suit code-focused corridor illumination needs and integrate with existing emergency lighting circuits.
  • Warehouses and manufacturing floors: High-capacity models handle larger loads and keep task areas and egress routes lit during short-duration outages.
  • Healthcare and municipal facilities: Multiple voltage options and robust steel housing generally match institutional installation requirements and longevity expectations.
  • Office and retail retrofits: Compact-dimension SKUs with 3W LED head options typically fit into constrained spaces while offering energy-efficient emergency lighting.

Not Recommended For

  • Outdoor or wet-location applications: Units lack an explicit IP/outdoor rating in the provided specifications; consider weather-rated emergency enclosures for exterior installations.
  • Specialized electrical environments needing Class E dielectric protection: If dielectric or specialized electrical protections are required, evaluate alternative emergency lighting categories designed for those conditions.

Professional Applications

Workers Who Rely on This Equipment

  • Electricians: Select and hardwire the correct 120/347 VAC input model and confirm installation wiring per manufacturer instructions and local codes.
  • Maintenance Technicians: Perform monthly tests, replace batteries and lamp heads when capacity degrades, and follow manufacturer-recommended inspection routines.
  • Facility Managers: Specify wattage capacity and SKU configurations to meet egress lighting plans and coordinate periodic service.
  • Safety Coordinators: Integrate units with exit signs and fire alarm systems to support coordinated emergency lighting strategies.
  • Building Owners: Approve unit selection and schedule lifecycle replacement planning aligned with operational needs.

Complete Safety Equipment Solutions

Complementary Safety Gear

The Battery Unit works alongside exit signs, fire alarms, and backup generators to form a comprehensive emergency power and illumination strategy. Using layered safety equipment generally supports code compliance and operational continuity during brief outages.

Recommended Equipment Combinations

  • Commercial corridors: Battery Unit + exit signs + hardwired emergency lighting fixtures + fire alarm interface
  • Warehouse aisles: High-capacity Battery Unit + LED emergency heads + backup generator connection
  • Healthcare facilities: Battery Unit + redundant emergency fixtures + regular testing and maintenance schedules

Selection Guide and Product Suitability

When to Choose This Product

Choose models from the EBST series when you need CSA Certified to C22.2 #141.15 listed emergency battery units with 120/347 VAC input and selectable PAR18 head options. Select higher wattage SKUs for large-scale facilities and compact models for retrofit offices or retail spaces.

Key Evaluation Factors

  • Required wattage capacity and total fixture load
  • Voltage option (6V, 12V, 24V) that matches existing circuits
  • Head style preference: 3W LED for efficiency or 9W T/standard PAR18 for traditional lamp types
  • Physical dimensions and mounting constraints for retrofit vs new construction

Limitations and Alternative Considerations

This series may not suit outdoor, wet, or specialized dielectric applications; consider weatherproof or purpose-built emergency enclosures and Class-rated units for those cases. Available from All Safety with standard, expedited, or overnight shipping to suit project timelines.

Daily Use and Maintenance

Workplace Integration — How do I install or adjust?

Installers typically hardwire the Battery Unit per manufacturer instructions or use the included 3-1/2 ft line cord for temporary power; confirm the correct 120/347 VAC feed before final connection. Adjust lamp head aiming and verify illumination coverage during commissioning.

Care and Replacement Guidelines — When to replace?

Follow manufacturer instructions for monthly and annual functional testing and schedule battery replacement when capacity degrades or per the recommended lifecycle. Clean the steel housing with a damp cloth, avoid harsh chemicals, and store spare batteries in a cool, dry place per manufacturer guidance.

Ordering and Delivery

How to Order and Verify SKU Configurations

Confirm required voltage, wattage capacity, head style (3W LED or 9W T PAR18 heads), and physical dimensions before placing an order since SKU configurations vary across the EBST series. Contact All Safety or your distributor to verify SKU fit for your installation and to arrange shipping and post-sale support.

View AllClose