BUY IN BULK & SAVE | $250+ = FREE SHIPPING | $500+ = 5% OFF + FREE SHIPPING | $1000+ = 7% OFF + FREE SHIPPING | $2000+ = 10% OFF + FREE SHIPPING | DISCOUNT APPLIED TO CART

Draeger

Pac 8500 CO-H2 CP (CA) | Draeger

(No reviews yet) Write a Review
SKU:
8328262
$1,195.33

Description

The Dräger PAC 8500 CO-H2 CP (CA) is a single-gas personal gas detector designed specifically for the detection of carbon monoxide (CO) and hydrogen (H2) gases in industrial environments. This device is equipped with a CO/H2-compensated sensor, which eliminates the cross-sensitivity issues typically associated with hydrogen exposure when monitoring carbon monoxide levels. The PAC 8500 is California-compliant (CA), meaning it meets the specific regulatory standards set forth by the state of California for gas detectors, including those related to environmental safety and performance.

Key Features:

  1. CO/H2-Compensated Sensor:

    • The PAC 8500 is equipped with an advanced CO/H2-compensated sensor. This special sensor is designed to eliminate the cross-sensitivity typically caused by hydrogen when detecting carbon monoxide. In many industrial environments, the presence of hydrogen can interfere with the accurate detection of carbon monoxide, but with the PAC 8500’s compensatory technology, this issue is effectively addressed.

    • This makes the PAC 8500 ideal for hydrogen-rich environments (such as refineries, chemical plants, and hydrogen production facilities) where both gases might be present.

  2. Single-Gas Detection:

    • The Dräger PAC 8500 is a single-gas detector, focused solely on detecting carbon monoxide (CO) in the air. This makes it highly specialized for environments where CO detection is critical, such as in confined spaces, manufacturing, and facilities dealing with combustion processes.

    • While the PAC 8500 detects only CO, its compensated sensor ensures accurate readings even in the presence of hydrogen.

  3. California Compliant:

    • The California-compliant (CA) designation ensures that the PAC 8500 meets the stringent California state regulations for air quality monitoring and hazardous gas detection. California’s environmental standards are among the most stringent in the U.S., meaning the PAC 8500 meets a high standard of safety and reliability for workplace use.

    • This compliance makes the PAC 8500 particularly valuable for businesses operating in California or those looking to meet high safety standards.

  4. Compact, Robust, and Lightweight:

    • The PAC 8500 is designed for personal use and is compact and lightweight, making it easy for workers to carry it throughout their shifts.

    • The device is small enough to fit in a worker's pocket, but its robust design ensures that it can withstand the rough conditions often found in industrial settings.

  5. Long Battery Life:

    • The PAC 8500 is equipped with a long-lasting rechargeable battery that ensures reliable operation over extended periods of use. It offers up to 2 years of continuous service, which minimizes downtime and maintenance costs.

    • The battery’s life depends on environmental factors and usage, but the device is designed for reliability during long work shifts.

  6. Visual, Audible, and Vibrating Alarms:

    • The PAC 8500 features multiple alarm types, including visual (flashing LED), audible (loud alarm), and vibrating alerts, which activate when CO levels exceed the pre-set threshold.

    • These alarms are essential for alerting the worker to the presence of dangerous CO concentrations in the environment and ensuring a rapid response.

  7. Clear LCD Display:

    • The device has an easy-to-read LCD screen that shows real-time gas concentration readings (in ppm). This display is backlit for visibility in low-light conditions and ensures that workers can quickly assess the gas concentration levels.

    • The display also shows the battery status, alarm thresholds, and other important data.

  8. Ease of Use:

    • The PAC 8500 is designed to be user-friendly, with one-button operation for turning on/off and operating the device.

    • Simple and intuitive controls minimize the learning curve, allowing workers to start using the device with minimal training.

  9. Durable Construction:

    • Built to withstand harsh environments, the PAC 8500 has a rugged design that is shock-resistant and water-resistant (IP68 rated).

    • Its durability ensures reliable performance even in challenging conditions like dusty environments, wet areas, or extreme temperatures.

  10. Maintenance and Calibration:

    • Routine calibration of the device is made easy, with options for manual calibration or using Dräger’s X-dock calibration station.

    • Automatic calibration ensures accuracy and reliability in gas detection, with the device notifying the user when a calibration is due.


Specifications:

  • Gas Detected: Carbon Monoxide (CO) with hydrogen compensation.

  • Detection Range:

    • CO: 0 - 1000 ppm.

    • H2 Compensation: Hydrogen concentration does not interfere with CO detection.

  • Alarm Types:

    • Visual: Flashing LED.

    • Audible: 95 dB(A) alarm.

    • Vibrating: Ensures alerts are noticeable even in noisy environments.

  • Battery Life:

    • Up to 2 years (depends on usage).

    • Rechargeable.

  • Operating Temperature Range:

    • -20°C to +50°C (-4°F to 122°F).

  • Ingress Protection:

    • IP68: Dust-tight and water-resistant, submersible in water.

  • Display: LCD screen with backlight, displaying real-time gas concentrations, battery status, and alarm thresholds.

  • Dimensions: Compact and portable, typically 110 x 60 x 35 mm (varies slightly depending on model).

  • Weight: Approx. 150-200 grams.

  • Compliance: California State requirements for industrial gas detectors.


Benefits of the PAC 8500 CO-H2 CP (CA):

  1. Enhanced Safety in Hydrogen-Rich Environments:

    • By using a CO/H2-compensated sensor, the PAC 8500 ensures accurate CO detection even in environments with significant hydrogen presence, such as refineries, petrochemical plants, and hydrogen production facilities.

  2. California Regulatory Compliance:

    • The device is specifically designed to meet California’s stringent safety standards, ensuring that companies operating in California or similar markets comply with safety regulations.

  3. Dependable Alarms:

    • The multiple alarms ensure that workers are immediately alerted when gas levels reach dangerous concentrations, giving them the opportunity to take quick action to protect themselves.

  4. Low Maintenance and Easy Operation:

    • The PAC 8500 offers low-maintenance operation with automatic calibration and a simple one-button interface, making it an excellent choice for businesses with high turnover or those in need of a device that’s easy to deploy and use.

  5. Durability and Reliability:

    • With an IP68 rating and shock-resistant housing, the PAC 8500 is built to last in harsh industrial environments, reducing the need for frequent replacements.

  6. Cost-Effective:

    • The long battery life and minimal maintenance required make the PAC 8500 a cost-effective solution for industrial gas detection. It offers reliable performance without the ongoing costs of replacing consumables frequently.


Applications:

  • Chemical and Petrochemical Plants: Monitoring CO in environments where hydrogen and carbon monoxide are present.

  • Refineries and Manufacturing: Where CO exposure can occur due to industrial processes, particularly in the presence of hydrogen.

  • Confined Space Entry: Workers who enter confined spaces where hazardous gases may accumulate need reliable detection, and the PAC 8500 ensures safety with its hydrogen-compensated sensor.

  • Laboratories and Research: Especially in environments where hydrogen and CO are used or produced.


Optional Accessories:

  • Dräger X-dock Calibration Station: For easy calibration and maintenance of the PAC 8500.

  • Carrying Cases: To protect the device during transport and storage.

  • Calibration Gas Kits: For ensuring accurate calibration with the correct CO and H2 gas concentrations.


Conclusion:

The Dräger PAC 8500 CO-H2 CP (CA) is an essential safety tool for industries where workers are at risk of exposure to carbon monoxide and hydrogen gases. Its hydrogen-compensated sensor provides accurate CO readings, even in the presence of hydrogen, while the California-compliant design ensures adherence to high safety standards. Combining durability, ease of use, and advanced gas detection technology, the PAC 8500 is an excellent choice for ensuring the safety of workers in hazardous environments.

View AllClose