Draeger
Test Gas Calibration Gas 58 L | Draeger
- SKU:
- 4502155/4594564/4594604/4594626/4594957/4594962/4594964/4594977/4597050/4597057/4597106/4597128
Description
Test gas, Calibration Gas canister, 58L, 25 ppm H2S in N2. Used for calibration and bump testing of gas detection equipment.
Test gas, Calibration Gas canister, 58L, 5 ppm NO2 in N2. Used for calibration and bump testing of NO2 gas detectors.
Test gas, Calibration Gas canister, 58L, mixture of CH4, O2, CO, SO2 in N2. Designed for multi-gas detector calibration.
Test gas, Calibration Gas canister, 58L, 25 ppm HCl in N2. For calibration of HCl gas detection instruments.
Test gas, Calibration Gas canister, 58L, 50 ppm NH3 in N2. For calibrating and bump testing of ammonia gas detectors.
Test gas, Calibration Gas canister, 58L, 10 ppm HCN in N2. For calibrating HCN gas detection equipment.
Test gas, Calibration Gas canister, 58L, 5 ppm Cl2 in N2. Used for Cl2 detector calibration and maintenance.
Test gas, Calibration Gas canister, 58L, 10 ppm NO2 in N2. For calibration of NO2 gas detection devices.
Test gas, Calibration Gas canister, 58L, 10 ppm SO2 in N2. For calibration of sulfur dioxide detectors.
Test gas, Calibration Gas canister, 58L, 0-0.5 ppm PH3 in N2. Precision calibration for phosphine gas detectors.
Test gas, Calibration Gas canister, 58L, CH4, CO, NO2, O2 in N2. Multi-gas mix for instrument calibration.
Test gas, Calibration Gas canister, 58L, CH4, CO, H2S, O2, CO2 in N2. Suitable for 5-gas detector calibration.
The Test Gas Calibration Gas 58 L by Draeger is a premium calibration gas mixture designed for the accurate calibration and functional testing of gas detection instruments. This cylinder contains a carefully balanced blend of various gases at precise concentrations, enabling users to calibrate portable and fixed gas detectors for a wide range of toxic, combustible, and asphyxiant gases. It’s an essential tool for ensuring the accuracy, reliability, and safety of gas detection systems in industrial, environmental, and laboratory applications.
Key Features:
-
Gas Mixture Components: The 58 L cylinder contains a complex blend of gases, each at specific concentrations, designed to test a variety of detection sensors:
-
25 ppm H₂S/N₂ (Hydrogen Sulfide in Nitrogen)
-
5 ppm NO₂/N₂ (Nitrogen Dioxide in Nitrogen)
-
CH₄ (Methane)
-
O₂ (Oxygen)
-
CO (Carbon Monoxide)
-
SO₂/N₂ (Sulfur Dioxide in Nitrogen)
-
25 ppm HCl/N₂ (Hydrogen Chloride in Nitrogen)
-
50 ppm NH₃/N₂ (Ammonia in Nitrogen)
-
10 ppm HCN/N₂ (Hydrogen Cyanide in Nitrogen)
-
5 ppm Cl₂/N₂ (Chlorine in Nitrogen)
-
10 ppm NO₂/N₂ (Nitrogen Dioxide in Nitrogen)
-
10 ppm SO₂/N₂ (Sulfur Dioxide in Nitrogen)
-
0-0.5 ppm PH₃/N₂ (Phosphine in Nitrogen)
-
CH₄, CO, NO₂, O₂/N₂ (Methane, Carbon Monoxide, Nitrogen Dioxide, Oxygen in Nitrogen)
-
CH₄, CO, H₂S, O₂, CO₂/N₂ (Methane, Carbon Monoxide, Hydrogen Sulfide, Oxygen, Carbon Dioxide in Nitrogen)
-
-
Cylinder Size: Comes in a 58 L cylinder, providing ample gas volume for multiple calibration cycles. This size is ideal for long-term use in larger facilities or for frequent calibration needs.
-
High Precision: The gas mixture is formulated to precise concentrations, ensuring that your calibration results are accurate and consistent. This precision is critical for ensuring the proper functioning of gas detection equipment, helping to meet safety and regulatory standards.
-
Compatibility: Designed for use with Draeger gas detection instruments as well as other compatible detection systems, making it versatile for various industries. It can calibrate multiple types of sensors, including those for toxic gases (like H₂S, CO, NO₂), combustible gases (like CH₄), and asphyxiant gases (like O₂).
-
Reliability and Safety: Meets industry safety standards and offers a stable gas mixture with a long shelf life, minimizing the need for frequent gas replacement. Ensures the safety of workers by calibrating gas detectors to react accurately to hazardous conditions.
-
Multi-Gas Calibration: This cylinder includes a broad range of gases—ensuring that you can calibrate multiple detectors for different gases in one cycle, saving time and resources.
Applications:
-
Industrial Safety: Essential for calibrating gas detection systems used in hazardous environments, such as chemical plants, oil and gas operations, and manufacturing facilities. Ensures that gas detectors are sensitive to harmful gases like H₂S, CO, and SO₂, which are commonly encountered in these industries.
-
Environmental Monitoring: Used in environmental testing for calibrating equipment that monitors air quality and emissions. Gases such as NO₂, SO₂, and CO₂ are key indicators of air pollution and industrial emissions.
-
Laboratory and Research: Useful in laboratories for precise calibration of analytical instruments used in research or academic settings, particularly when dealing with toxic or hazardous gases like HCN, NH₃, or PH₃.
-
Fire Departments & Hazardous Materials Response: Firefighters, emergency responders, and hazmat teams can use this calibration gas to ensure that their gas detection equipment is accurately calibrated for swift and effective response to hazardous situations.
-
Compliance and Regulatory Testing: Ensures compliance with workplace safety regulations and environmental standards by providing accurate calibration results for gas detectors used in regulatory testing and inspections.
Benefits:
-
Multi-Gas Testing: Allows calibration of instruments to detect a broad spectrum of gases in a single test, making it a versatile solution for industries with varying gas detection needs.
-
Reduced Downtime: The high volume of gas (58 L) ensures that you can complete multiple calibrations before needing a refill, improving operational efficiency.
-
Accurate and Consistent: Ensures that your detectors are working within the specified tolerances, providing accurate safety readings and helping prevent dangerous exposure to hazardous gases.
The Draeger Test Gas Calibration Gas 58 L is an essential tool for anyone who relies on accurate gas detection to ensure safety and compliance in their operations. Whether in industrial settings, research labs, or environmental monitoring, this calibration gas ensures that detection systems remain reliable and precise, even in the most demanding environments.
Available Variants:
- 25 ppm H2S/N2 (4502155)
- 5 ppm NO2/N2 (4594564)
- CH4, O2, CO, SO2/N2 (4594604)
- 25 ppm HCL/N2 (4594626)
- 50 ppm NH3/N2 (4594957)
- 10 ppm HCN/N2 (4594962)
- 5 ppm CL2/N2 (4594964)
- 10 ppm NO2/N2 (4594977)
- 10 ppm SO2/N2 (4597050)
- 0-0.5 ppm PH3/N2 (4597057)
- CH4, CO, NO2, O2/N2 (4597106)
- CH4, CO, H2S, O2, CO2/N2 (4597128)